VOLTAGE | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
kW | kVA | kW | kVA | ||
400/230 | 9.6 | 12 | 8.6 | 11 | 17 |
STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utilitysource. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 %overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.
General Characteristics
Model Name | APD 12 E |
Frequency (Hz)
|
50 |
Fuel Type
|
Diesel |
Engine Made and Model
|
AKSA A2CRX08 |
Alternator Made and Model
|
Mecc Alte |
Control Panel Model
|
P4520 |
Canopy
|
AK 01 |
Engine
|
AKSA |
Engine Model
|
A2CRX08 |
Number of Cylinder (L)
|
2 cylinders – in line |
Bore (mm.)
|
80 |
Stroke (mm.)
|
79 |
Displacement (lt.)
|
0.794
|
Aspiration
|
Naturally Aspirated
|
Compression Ratio
|
23:1 |
RPM (d/dk)
|
3000
|
Fuel Type
|
Diesel
|
Governor System
|
Electronic
|
Oil Capacity (lt.)
|
2.3 |
Coolant Capacity (lt)
|
6.4 |
Cooling Fan Air Flow (m³/min.)
|
1 |
Radiator Air Flow (m³/min.)
|
48 |
Exhaust Gas Flow (m³/min.)
|
2.07 |
Exhaust Gas Temperature(°C)
|
500 |
Operating Voltage (Vdc)
|
12 Vdc |
Fuel Cons. Prime With %100 Load (lt/hr)
|
4 |
Manufacturer
|
Mecc Alte
|
Frequency (Hz)
|
50 |
Power (kVA)
|
10 |
Design
|
With Brush, 2 Pole
|
Rated Power Factor
|
0.8 |
Phase
|
3 |
VOLTAGE (V)
|
400/230 |
Insulation System
|
H |
MODEL
|
AK 01
|
LENGHT
|
1152 |
WIDTH
|
776 |
HEIGHT
|
890
|
DRY WEIGHT (kg.)
|
270 |
TANK CAPACITY (lt.)
|
15 |
2. Emergency stop push button.
3. Control panel
4. Corrosion-resistant locks and hinges.
5. Oil could be drained via valve and a hose
6. Exhaust system in the canopy.
7. Special large access doors for easy maintanance
8. Base frame -fuel tank.
9. Lifting Points.
10. Cover for radiator water filling
INTRODUCTION
Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirementsand provide optimum protection from inclement weather and development by our specialist acoustic engineers. Ourmodular designed sound insulated canopies (8 – 275kVA) fit directly to the open generator set to provide ease of access forservicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed tooptimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
Control Panel
Control Module | DSE |
Control Module Model | P4520 |
2. Menu Navigation Buttons.
3. Automatic Location.
4. Manual Start Button.
5. Reset/Stop Button.
Devices
-DSE, model 4520 Auto Mains Failure control module.
-Battery charger.
-Emergency stop push button and fuses for control circuits
The DSE4520 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving true first up fault condition of Gen. Set failure.The LCD display indicates the fault
-LCD display makes information easy to read.
-4-line, 64 x 132 pixel display.
-Automatically transfers between mains (utilty) and generator power.
-Manual programming on front panel.
-User-friendly set-up and button layout.
-Remote start.
-Event logging (5)showing date and time.
Manufacturer reserves the right to make changes in the model, technical specifications, color, equipment, accessories and images without prior notice.
(11.05.2017)
STATIC BATTERY CHARGER
– Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
Battery charger models’ output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 24
V for 24 V . Input 198 – 264 volt AC.
Proline DC12V charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance
with linear alternatives.